How to check the water pressure of Weineng wall-mounted boiler
As an important piece of equipment for home heating, the stability of the water pressure of the Weineng wall-hung boiler is directly related to the normal operation and safety of the equipment. Recently, the method of checking and adjusting the water pressure of Weineng wall-mounted boilers has become a hot topic among users. This article will give you a detailed introduction to how to check the water pressure of a Weineng wall-mounted boiler, as well as common problems and solutions, to help you easily deal with water pressure problems in daily use.
1. The normal range of water pressure of Weineng wall-mounted boiler

The water pressure of Weineng wall-mounted boilers usually has a standard range. Exceeding or falling below this range may cause the equipment to operate abnormally. The following is the normal range of water pressure for Weineng wall-mounted boilers:
| water pressure status | Pressure value (bar) |
|---|---|
| normal range | 1.0-2.0 |
| Too low (need to replenish water) | < 1.0 |
| Too high (needs drainage) | > 2.0 |
2. How to check the water pressure of Weineng wall-mounted boiler
The water pressure of the Weineng wall-mounted boiler is usually displayed by a pressure gauge. The following are the specific steps to check the water pressure:
1.Find the pressure gauge: The pressure gauge of a Weineng wall-mounted boiler is usually located on the front or side of the device. It is a round or square dial marked with a pressure scale (unit: bar).
2.Observe the pressure value: When the equipment is at rest (not running), the pointer of the pressure gauge should point between 1.0 - 2.0 bar. If the pointer is below 1.0 bar, the water pressure is too low; if it is above 2.0 bar, the water pressure is too high.
3.Check pressure changes during operation: When the wall-hung boiler is heating, the water pressure will rise slightly, but usually it should not exceed 2.5 bar. If the pressure is too high while running, there may be a problem with the system.
3. Common causes and solutions for abnormal water pressure
The following are common causes of abnormal water pressure in Weineng wall-hung boilers and their corresponding solutions:
| Problem phenomenon | Possible reasons | Solution |
|---|---|---|
| Water pressure too low (<1.0 bar) | The system is leaking and water has not been replenished for a long time. | Check whether the pipe is leaking. If there is no leakage, replenish the water. |
| Water pressure is too high (>2.0 bar) | Too much water, expansion tank failure | Drain water to the normal range through the drain valve, or contact after-sales service to check the expansion tank. |
| Large pressure fluctuations | There is an air or water pump failure in the system | Exhaust operation or contact professionals for maintenance |
4. How to adjust the water pressure of Weineng wall-mounted boiler
If the water pressure is abnormal, you can adjust it by following these steps:
1.Water replenishment operation (when water pressure is too low):
- Turn off the power to the boiler and locate the refill valve (usually located at the bottom of the unit).
- Rotate the water replenishment valve counterclockwise and observe the pressure gauge after hearing the sound of water flow. When the pressure reaches about 1.5 bar, close the water replenishment valve clockwise.
- Restart the boiler and check if the pressure is stable.
2.Drainage operation (when water pressure is too high):
- Turn off the power supply to the wall-hung boiler and locate the drain valve or exhaust valve of the radiator.
- Slowly open the drain valve to release some of the water and close the valve when the pressure gauge drops to about 1.5 bar.
- Restart the device and check if the pressure is normal.
5. Daily maintenance suggestions
In order to ensure the stability of the water pressure of the Weineng wall-mounted boiler, it is recommended that users perform the following maintenance regularly:
-Check water pressure monthly, make sure the pressure is within the normal range.
-Vent the system once a year, to avoid air accumulation affecting water pressure.
-Pay attention to whether pipes and valves are leaking, repair the leakage point in time.
-Turn off the water source when not in use for a long time, to avoid abnormal water pressure.
6. Summary
The water pressure of the Weineng wall-hung boiler is a key indicator of the normal operation of the equipment, and users should master the correct viewing and adjustment methods. By regularly checking the water pressure and handling abnormal problems in a timely manner, the life of the equipment can be effectively extended and the heating effect can be guaranteed. If you encounter a problem that cannot be solved by yourself, it is recommended to contact Vaillant official after-sales or professional maintenance personnel for processing.
check the details
check the details