2025-12-24 02:22:21 mechanical

How to refill Bosch wall-hung boiler

With the arrival of winter, the frequency of use of wall-hung boilers gradually increases, and water replenishment is one of the important aspects of daily maintenance of wall-hung boilers. As a well-known brand in the market, Bosch wall-mounted boilers have also attracted much attention from users for their water replenishment operation. This article will introduce in detail the water replenishment steps, precautions and FAQs of Bosch wall-mounted boilers to help users easily complete the water replenishment operation.

1. Steps to replenish water for Bosch wall-hung boiler

How to refill Bosch wall-hung boiler

The following are detailed steps for replenishing water in Bosch wall-mounted boilers for users’ reference:

stepsOperating Instructions
1. Check the pressure gaugeFirst, observe the pressure gauge of the wall-hung boiler. The normal pressure range is 1-1.5 bar. If the pressure is below 1 bar, water needs to be added.
2. Turn off the power of the wall-hung boilerBe sure to turn off the power of the wall-hung boiler before replenishing water to ensure safe operation.
3. Find the water replenishment valveThe refill valve is usually located at the bottom of the boiler and is a black or blue knob labeled "Refill".
4. Slowly open the water replenishing valveTurn the water replenishing valve counterclockwise while observing the pressure gauge. Stop replenishing water when the pressure reaches 1.5 bar.
5. Close the water replenishment valveOnce rehydration is complete, turn the rehydration valve clockwise to ensure it is fully closed.
6. Restart the wall-hung boilerTurn on the power supply to the wall-mounted boiler and check whether it is operating normally.

2. Precautions for hydration

During the hydration process, you need to pay attention to the following points to avoid problems caused by improper operation:

Things to noteDescription
1. Do not exceed the upper pressure limit when replenishing waterExcessive pressure will cause the wall-hung boiler to automatically release pressure and even damage internal components.
2. The water replenishment valve must be completely closedIf the water replenishment valve is not closed tightly after replenishing water, it may cause continuous water leakage.
3. Check pressure regularlyIt is recommended to check the pressure gauge once a week to ensure that the wall-mounted boiler is in normal working condition.
4. Avoid quick operations when replenishing waterOpen the water replenishment valve slowly to prevent pressure from rising suddenly.

3. Frequently Asked Questions

The following are common problems and solutions that users may encounter when using Bosch wall-mounted boilers to refill water:

questionSolution
1. The pressure is still too low after replenishing water.Check the system for leaks or contact professional maintenance personnel.
2. The water replenishment valve cannot be opened or closedIt may be that the valve core is rusted. Try tapping lightly or applying lubricant. If that doesn't work, replace the valve.
3. The pressure gauge displays abnormallyThe pressure gauge may be faulty and it is recommended to replace it with a new one.
4. The wall-mounted boiler does not work after replenishing water.Check that the power is on, or reset the boiler system.

4. Summary

The water replenishing operation of Bosch wall-hung boiler is not complicated, just follow the correct steps. The key is to pay attention to the pressure gauge reading to avoid over- or under-hydration. If you encounter a problem that cannot be solved, it is recommended to contact professional maintenance personnel in time to avoid causing greater damage. I hope this article can help users successfully complete the water replenishment operation of the wall-mounted boiler to ensure the comfort and safety of heating in winter.

Next article
  • How to refill Bosch wall-hung boilerWith the arrival of winter, the frequency of use of wall-hung boilers gradually increases, and water replenishment is one of the important aspects of daily maintenance of wall-hung boilers. As a well-known brand in the market, Bosch wall-mounted boilers have also attracted much attention from users for their water replenishment operation. This article will introduce in detail the w
    2025-12-24 mechanical
  • How to change heating from series to parallelWith the arrival of winter, the renovation of heating systems has become the focus of attention for many families. In particular, changing the traditional series heating system to a parallel type has become one of the hot topics in the past 10 days. This article will provide you with a detailed analysis of the transformation method of heating from series to parallel in ter
    2025-12-21 mechanical
  • How about Honeywell fresh air system?In recent years, as people's attention to indoor air quality continues to increase, fresh air systems have gradually become standard equipment in home and office environments. As a world-renowned provider of air purification solutions, Honeywell’s fresh air system has attracted much attention. This article will comprehensively analyze the performance of Honeywell's fresh air sys
    2025-12-19 mechanical
  • How to release air from floor heatingWith the advent of winter, the frequency of use of floor heating has gradually increased, but many users have reported that the floor heating system has problems such as no heat or loud noise. This is usually caused by air accumulation in the pipes. Venting floor heating is a key step in solving this problem. This article will introduce in detail the correct method of venting floo
    2025-12-16 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line